PRODUCT TECHNICAL DATASHEET
TW110/2000
New
-
Brushless
-
Intensive use
-
4096 PPR Digital Magnetic Encoder
-
-
CODE DESCRIPTION PCS/PALLET
-
-
TW110/2000 Electromechanical BRUSHLESS motor, low voltage, super intensive use, with SENSORED digital magnetic encoder at 4096 PPR, irreversible ideal for sliding gates up to 2000 kg, with digital controller in pre-wired plastic box series B70. 30
-
-
-
-
-
PRODUCT TECHNICAL SPECIFICATIONS
-
-
Max gate weight 2000 kg
-
-
Power line supply 230V AC - 50Hz
-
-
Motor power supply 36V
-
-
Power rating 240W
-
-
Frequency of use Intensive use
-
-
Thrust 570N
-
-
Operating temperature -20+55°C
-
-
Protection level IP44
-
-
Reductor Type Irreversible
-
-
Manoeuvre speed 12 m/min (0.16 m/s)
-
-
Limit switch Without limit switches - optional
-
-
Onboard control unit B70/1THP
-
-
Encoder Digital magnetic encoder SENSORED, 4096 PPR
-
-
Batteries recovery Optional 2 external battery 12V 4,5AH
-
-
Type exit gear Z17/mod 4
-
-
Operating cycles per day (opening/closing - 24 hours no stop) 150000
-
-
Maximum dimension product in mm (L x W x H) 185 x 160 x 333
-
-
Product weight packed (Kg) 17,4
-
-
Number items per pallet/box 30
-
-
-
PRODUCT DIMENSIONS AND PREPARING FOR INSTALLATION
-
-
-
-
-
-
DIMENSIONS
|
-
-
DIMENSIONS
-
-
-
PRODUCT PREPARING FOR INSTALLATION
-
-
-
-
-
-
PREDISPOSITION FOR STANDARD INSTALLATION
PRODUCT ACCESSORIES
-
-
-
-
-
-
B71/BCHP/EXT
Kit for emergency batteries charger for Brushless digital controller EDGE1/BOX - B70/1DCHP - B70/1THP 36V DC with plug-in card, with 2 recovery batteries 12V DC, 4.5 Ah. Box case included.
|
-
-
B71/BCHP/BOX
Kit for emergency batteries charger for Brushless digital controller EDGE1/BOX - B70/1DCHP - B70/1THP 36V DC. Box case included and without recovery batteries.
|
-
-
B71/PBX36/BOX
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 230V AC.
|
-
-
B71/PBX36/BOX/115
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 115V AC.
|
-
-
B71/PBX/BOX
Hybrid inverter, “Full Solar” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels for powering the brushless digital controllers.
|
-
-
GA550
Galvanised steel rack 22x22x1000 module 4.
-
-
-
-
-
GA551
Galvanised steel rack 30x12x1000 module 4 with spacers and screws.
|
-
-
GA554
Pocket of 6 spacers (2,5 cm) and screws.
|
-
-
GA553
Nylon rack module 4 with 6 connectors L.1000.
|
-
-
GA557
Roger Technology nylon rack module 4 with 6 connectors L.1000.
|
-
-
GA558
Roger Technology nylon rack module 6 with 6 connectors L.1000.
|
-
-
LT328
Pinion Z17 mod. 4 with increased thickness H.38 for series R30 - G30 - TW110 - E30 (except BG30/804/HS - BG30/1504/HS - TW110/1000/HS).
-
-
-
-
-
LT331
Pinion Z11 mod. 6 only for series G30 - BG30 - TW110 (except BG30/804/HS - BG30/1504/HS - TW110/1000/HS).
|
-
-
MC783
Pair of increased magnets for magnetic limit switch, only for GA558.
|
-
-
MC786
NORD-SOUTH magnetic limit switches for TW110.
|
-
-
MC787
NORD-SOUTH magnetic limit switch kit and brackets for TW110.
|
-
-
RL671
Metallic wire length 3 m for release from outside.
|
-
-
B74/BCONNECT vers. HW2
Module WI-FI B-CONNECT - Remote management and programming system in IP web browser mode via Wi-Fi hot spot P2P connection for Brushless control units (B70/2ML - EDGE1 - CTRL - B70/1DC - B70/1DCHP - B70/1T - B70/1THP - F70/IPU36).
-
-
-
-
-
R99/C/001AL
Signboard "Automatic Opening" Aluminium version.
|
-
-
R99/C/001
Signboard "Automatic Opening".
| | | | | | | | | | |
-
-