KIT PRODUCT TECHNICAL DATASHEET
KIT EDGE1/21
Brushless
-
Intensive use
-
Composition KIT EDGE1/21
-
-
CODE DESCRIPTION QTY
-
-
EDGE1/BOX Digital control 36V for 2 BRUSHLESS motor, in plastic box. With 2-channel radio receiver installed on board. 1
-
-
SYNUS/2 Dual code transmitter (modality fixed code or rolling code), 433,92 MHz, 2 channels, with copy function. 2
-
-
R90/F4ES Pair of external photocells synchronized 24V AC/DC, up to a maximum of 4 pairs of photocells. 1
-
-
R91/AN1/P1 Antenna designed for wall fixing. 1
-
-
R99/C/001 Signboard "Automatic Opening". 1
-
-
-
PRODUCT TECHNICAL SPECIFICATIONS
-
-
Power line supply 230V AC - 50 Hz
-
-
Operating temperature -10+55 C°
-
-
Protection level IP54
-
-
N. motors activated 2 Brushless motor
-
-
Max power per motor 250W
-
-
Max courtesy light charge 100W 230V AC - 40W 24V AC/DC
-
-
Max power gate open light 3W (24V DC)
-
-
Max voltage accessories output 20W (24V DC)
-
-
Eletrical-Lock max power 15W (12V DC)
-
-
Flash light voltage 24V DC
-
-
Max flashing light charge 25W
-
-
Battery Optional
-
-
Maximum dimension product in mm (L x W x H) 330 x 230 x 115
-
-
Product weight packed (Kg) 5,9
-
-
Number items per pallet/box 49
-
-
-
PRODUCT ACCESSORIES
-
-
-
-
-
-
B71/BCHP/EXT
Kit for emergency batteries charger for Brushless digital controller B70/1DCHP - B70/1THP - EDGE1/BOX 36V DC with plug-in card, with 2 recovery batteries 12V DC, 4.5 Ah. Box case included.
|
-
-
B71/BCHP/BOX
Kit for emergency batteries charger for Brushless digital controller B70/1DCHP - B70/1THP - EDGE1/BOX 36V DC. Box case included, without recovery batteries.
| | | | | | | | | | |
-
-